- The best training aid for teaching AC/DC motors and
generators, transformers, mechanical and electrical
loads
- Portable, safe and modular design
- Space-saving stackable units
- Includes more than 50 experiments dealing with
electrical engineering
- Quick and easy interconnection
- Visible construction and operation
|
| CL-125 Synchronizing Unit |
 |
- Used in teaching electrical
technology where a synchronizing switch is required for
alternator synchronization
- Following the connection of the
CL-125 with two different three phase power
supplies, three built-in red lamps on the front panel signal the
phase sequence and the frequency gap between the two supply
units
- Included in the basic CL-100
|
|
|
| CL-143 Variable Three Phase Power Supply |
 |
- Three phase input
- Fixed and variable three phase AC output
- Fixed and variable single phase AC output
- Included in the basic CL-100
|

|
| CL-148 DC Rectifier |
 |
- Used to teach the
principles of variable autotransformers and
rectifiers
- Power supplied by the
CL-143 fixed
or variable output
- Fixed and variable three phase input
- Fixed and variable DC output
- Included in the basic CL-100
|

|
| CL-151-1 S.C.R. DC Motor Speed Controller |
 |
- Switch and start indicator light
- Speed control adjustment
- Current limit adjustment for torque control
at full load
- Transient voltage protection and AC fuse
protection
- Minimum/maximum speed adjustment
- Acceleration trim pot adjustment
- Bridge assembly with built-in free wheeling diode
- Plug-in horsepower resistor
- Design with superior line and load voltage regulation
- Included in the basic CL-100
|

|
| CL-152 Three Phase Rheostat for Wound Rotor Motors |
 |
- Three adjustable single-phase rheostats mounted on the same shaft
and connected in wye
- Can be used for wound rotor motor applications
- Included in the basic CL-100
|

|
| CL-211 Synchronous Machine |
 |
- Designed to operate as a motor
or as
an alternator
- Its stator must be connected to the CL-143
- Its rotor must be linked to the CL-148 and works as a square cage when starting and
stopping
- Included in the basic CL-100
|

|
| CL-212 Wound-Rotor Induction Motor |
 |
- Works as either a motor or an alternator
- Its rotor consists of three phase windings connected to rings that are
mounted
on the shaft
- Gives a
torque that can be adapted
to the drive load
- Speed control is possible when connected
with the CL-152
- Included in the basic CL-100
|

|
| CL-213 Squirrel Cage Induction Motor |
 |
- Can be used as either
a motor or generator
- The three-stator windings may be
connected
in wye or delta
- Included in the basic CL-100
|

|
| CL-214 DC Machine |
 |
- Can be used as a
series, compound
and shunt motor or generator
- Perfect tool for teaching the
principles
of a DC motor/generator
- Included in the basic CL-100
|

|
| CL-223 Split-Phase Motor w/Starting Capacitor |
 |
- Designed to teach the principles of a splitphase
motor equipped with a starting capacitor specially
built for this type of motor
- Its centrifugal switch disconnects
the capacitor after a short time delay when starting the
motor
- Included in the basic CL-100
|

|
| CL-224 Capacitor Run Motor |
 |
- Single-phase unit that can be used to
teach the principles of the capacitor run motor
- Its capacitor is externally
mounted
- Included in the basic CL-100
|

|
| CL-225 Universal Motor |
 |
- Works similar to the DC series motor
and can be operated in any household AC frequency
or DC current
- Designed to teach the
principles of universal motors and it can serve as a variable speed
prime mover
- It operates on AC and DC voltages
- Included in the basic CL-100
|

|
| CL-231 Prony Brake |
 |
- Can be used as a mechanical load
- Provides the possibility to load a motor to determine experimentally its load characteristics
- Friction between the belt and the rotating disc is controlled through a handle
- Gives a reading of the force in N.m or lb.ft
- Included in the basic CL-100
|

|
| CL-246 Magnetic Particle Brake |
 |
- Stable shockless braking torque
- Rated torque available from zero speed
- Low moment of inertia and low residual torque
- Operation in either rotational direction
- Permits braking torque measurement
- Can be included in the basic CL-100
|

|
| CL-311 Variable Resistive Load Unit |
 |
- Can be used either as a single or three-phase
variable resistive load bank
- Designed to experiment the basic
principles of R-L and R-L-C circuits on AC and DC voltage
- consists of 9 individually switched load resistors arranged
in three identical groups
- Included in the basic CL-100
|

|
| CL-312 Variable Inductive Load Unit |
 |
- Can be used either as a single or three-phase
variable inductive load bank
- Designed to experiment the basic
principles of R-L and R-L-C circuits on AC and DC voltage
- consists of 9 individually switched load inductors arranged
in three identical groups
- Included in the basic CL-100
|

|
| CL-313 Variable Capacitive Load Unit |
 |
- Can be used either as a single or three-phase
variable capacitive load bank
- Designed to experiment the basic
principles of R-L and R-L-C circuits on AC and DC voltage
- consists of 9 individually switched load capacitors arranged
in three identical groups
- Included in the basic CL-100
|

|
| CL-314 Single Phase Transformer |
 |
- Designed to
demonstrate the applications and characteristics of
transformers
- Can be also used for experimentation
with the CL-148
- Consists of two distinct
primary windings and only one secondary winding, all
with several reduced capacity taps
- Included in the basic CL-100 (3 units)
|

|
| CL-413 Analaog Three Phase Wattmeter |
 |
- Consists of two 300-W
meters wired together to measure the real power in three phase
systems
- Switches are provided to invert
negative readings
- Included in the basic CL-100
|

|
| CL-420 DC Meter |
 |
- Designed to be used with
other Consulab units in electrical engineering
measurements for motor and generator experiments
- Included in the basic CL-100
|

|
| CL-421 Triple Four-Scale AC Ammeters |
 |
- Includes three (3) analog ammeters for
reading alternative current
- Each ammeter has
four (4) reading scales that are adapted to measure the
current in experiments with rotative machines,
electrical circuits or motor controllers
- Included in the basic CL-100
|

|
| CL-422 Triple Two-Scale AC Voltmeters |
 |
- Includes three (3) analog voltmeters for
reading AC voltages
- Each voltmeter has
two (2) reading scales adapted to measure the voltage in
experiments with rotative machines, electrical circuits,
or motor controllers
- Included in the basic CL-100
|

|
| CL-1003 Handheld Tachometer |
 |
- Provides a convenient, accurate way of
measuring rotary speeds
on all types of machine
- Used in non-contacting
measurements, the tachometer optically detects a reflective target on the
rotating object
- Its mechanical adaptor is used for reading shaft
rotation in contacting measurements
- Included in the basic CL-100
|
 |
| CL-1007 Rubber Coupling Sleeve |
 |
- Consists of a flexible sleeve made of
thermoplastic rubber
- Easy and safe to install when coupling
the CL-100 machines
- Allows for smooth transmission of
power
- Included in the basic CL-100
|

|
| CL-1010-00 Two-Machine Coupling Base |
 |
- Designed to couple
two (2) CL-100 machines
- Equipped with
wing screw anchors to safely bolt the machines before
the coupling experiments
- Included in the basic CL-100
|

|
| CL-1012 Safety Connecting Patch Cords |
 |
- Highly flexible safety connecting patch cords with 4-mm diameter safety piggy-back plugs
- The set contains:
- Ten (10) blue cords, 25 cm (L)
- Ten (10) yellow cords, 50 cm (L)
- Ten (10) red cords, 75 cm (L)
- Ten (10) black cords, 100 cm (L)
- One (1) green cord, 100 cm (L)
- Included in the basic CL-100
|

|